Basic Info.
Model NO.
Z-15GQ-B-C
Protection
Waterproof
Size
Small-Sized
Environment
﹤250℃
Breaking Capacity
Micro-Current
Application
Mouse
Certification
CE, CCC, Gwiec
Housing Color
Black(Green or Red Available)
Contact Resistance
30 Mohm Max
Protection Degree
IP40
Terminal Type
Solder
Enclosure Material
Plastic
Sample Order
Acceptable
Contact
Copper ( Silver Available)
Z-15gq-B-C
No Lever
Transport Package
Standard Packing.
Specification
Z-15GQ-B-C
Trademark
GWIEC
Origin
Wenzhou, Zhejiang, China
Production Capacity
50000
Product Description

Product Description
Characteristics
Virous of actuators, action position is adjustable
High switch on and off capacity(15A)
High accuracy
Wide range of operation speed
Ratings
NOTES:
1.Inductive load has a power factor of 0.4 min.(AC) and a time constant of 7 msec.max.(DC).
2.Lamp load has an inrush current of 10 times the steady-state current,while motor load has an inrush current of 6 times the steady-state current.
Characteristics

PS:If you can't find the exact type of your product.Please don't rush to go away.Contact me and your questions will be replied ASAP.Thank you for your time.
Virous of actuators, action position is adjustable
High switch on and off capacity(15A)
High accuracy
Wide range of operation speed
Ratings
Rated voltage | Nonidctive load (A) | inductive Load (A) | ||||||
Resistance Load | Lamp Load | Inductive Load | Motor Load | |||||
NC | NO | NC | NO | NC | NO | NC | NO | |
125VAC 250VAC 480VAC 600VAC | 10 5 3 1 | 3 2 1.5 1 | 1.5 1 0.8 0.5 | 10 5 3 1.5 | 5 3 1.5 1 | 2.0 1.0 0.8 0.5 | ||
8VDC 14VDC 30VDC 125VDC 250VDC | 10 10 6 0.8 0.4 | 6 6 4 0.2 0.1 | 3 3 3 0.2 0.1 | 10 10 6 0.8 0.4 | 6 6 4 0.2 0.1 |
1.Inductive load has a power factor of 0.4 min.(AC) and a time constant of 7 msec.max.(DC).
2.Lamp load has an inrush current of 10 times the steady-state current,while motor load has an inrush current of 6 times the steady-state current.
Characteristics
Operation spead | 1mm-2m/s |
Operating frequency | Mechanical:120 operations/minute Electical:30 operations/minute |
Contact resistance | 15mΩ max. (inital value) |
Insulation resistance | 100mΩ min. (below 500VDC) |
Dielectric strength | 1000VAC,50/60 Hz for 1 minute between terminals of the same polarity |
1,500VAC,50/60 Hz for 1 minute between current-carrying and non-current-carrying metal parts | |
1,500VAC,50/60 Hz for 1 minute between each terminal and ground | |
Vibration | 10-55Hz,1.5mm double amplitude |
Shock | Mechanical durable:1,000m/Sec²(about 100G'S) Malfunction:300m/Sec²(about 30G'S) |
Ambient temperature | Use: -10 to +80 °C |
Humidity | <95% RH |
Life | Mechanical:15,000,000 operations above(under rated OT) Electrical:500,000 operations above |
Weight | |
Degree of protection | IEC specification:IP40 |


PS:If you can't find the exact type of your product.Please don't rush to go away.Contact me and your questions will be replied ASAP.Thank you for your time.