Basic Info.
Model NO.
GW9
Installation
Outdoor High-voltage
Operation
Electric
Grounding Mode
Grounding
Movement Mode
Oscillating Type
Number of Poles
Unipolar
Grounding
Single Ground
Series
Two
Product Name
Shackle, Thimble, Hook, Anchor
Surface Finish
Hot DIP Galvanized
Transport Package
Wooden Case
Specification
CE, SGS, ISO
Trademark
OPTELEC
Origin
China
HS Code
7316
Production Capacity
3000 Set/Sets Per Month
Product Description
ISOLATOR SWITCH
The isolation switch is the high voltage switch equipment of single phase AC 50Hz. The product is suitable for power system switch on/off when system has voltage but no load.
The isolation switch adopts isolation hook rod to operate.
Application:
RH-B series outdoor high voltage isolate switch





The isolation switch is the high voltage switch equipment of single phase AC 50Hz. The product is suitable for power system switch on/off when system has voltage but no load.
The isolation switch adopts isolation hook rod to operate.
Application:
- The altitude shall be not more than 1000m
- The ambient temperature: -30degC ~+40degC ; Paramos: -40degC
- Wind pressue: <=700Pa (equals to 34m/s)
- Earthquake strength <=8degree
- Working place with no frequent vibration
- The installation site of ordinary type isolation switch should be kept away from gas, smoke, chemical deposition , salt-spray fog, dust and other explosive and corrosive items that seriously affect insulation and conductivity capacity of the isolator. The pollution-proof type isolator can be installed on the above polluted area but should be avoided from fire and explosion.

Type | Rated voltage (kV) | Rated current (A) | Limit current(kA) | 10sThermally stable current (kA) | |
Value Peak | Effective value RMS | ||||
(H)GW9-12G/200 | 12 | 200 | 5 | 9 | 5 |
(H)GW9-12G/400 | 12 | 400 | 21 | 15 | 10 |
(H)GW9-12G/630 | 12 | 630 | 35 | 25 | 14 |
(H)GW9-12G/800 | 12 | 800 | 55 | 35 | 20 |
(H)GW9-12G/1000 | 12 | 1000 | 80 | 45 | 28 |
(H)GW9-12G/1250 | 12 | 1250 | 120 | 55 | 39 |
(H)GW9-10/200A | 10 | 200 | 5 | 9 | 5 |
(H)GW9-10/400A | 10 | 400 | 21 | 15 | 10 |
(H)GW9-10/630A | 10 | 630 | 35 | 25 | 14 |
(H)GW9-10/800A | 10 | 800 | 55 | 35 | 20 |
(H)GW9-10/1000A | 10 | 1000 | 80 | 45 | 28 |
(H)GW9-10/1250A | 10 | 1250 | 120 | 55 | 39 |

Type | Rated voltage (kV) | Rated current (A) | Limit current(kA) | 10sThermally stable current (kA) | |
Value Peak | Effective value RMS | ||||
GWDCD1 | 12 | 630(1250) | 5 | 9 | 5 |
GWDCD2 | 12 | 630(1250) | 21 | 15 | 10 |
RH-B series outdoor high voltage isolate switch

Type | Rated voltage (kV) | Rated current (A) | 4S heat steady e.c (A) | Short current (A) | Impulse withstand voltage(kV) | Power-frenquency withstand voltage (kV) |
RH-B | 11 | 400 | 12500 | 31500 | 95 | 42 |
RH-B | 33 | 600 | 12500 | 31500 | 180 | 80 |